BTU to watts: how many watts does an air conditioner use?
Updated 2026-10-01 · BestGenerator team
We may earn a commission if you buy through our links, at no extra cost to you. As an Amazon Associate I earn from qualifying purchases.
Short answer: For heaters, 1 watt = 3.412 BTU per hour, so a 1,500 W heater gives about 5,100 BTU/h. An air conditioner is different: its BTU rating is heat it moves, not power it uses. Its electrical draw is roughly BTU ÷ EER, so a 12,000 BTU AC uses about 750 to 1,200 running watts, plus a start-up surge.
Your numbers
Your result
You need about 1,250 running watts and 2,500 starting watts.
Assumes you start big appliances one at a time, not all in the same second.
With 20% headroom (our rule of thumb): 1,500 W running / 3,000 W startingShow the maths
- Without headroom: 1,250 W running / 2,500 W starting
- Window AC (8,000 BTU): 750 W running, surge +1,250 W
- Fridge: 400 W running, surge +800 W
- Lights (LED, a few rooms): 100 W running, surge +0 W
- Running = sum of running watts × quantity = 1,250 W.
- Starting = running + the single biggest surge = 2,500 W.
What to look for
- Watts: 1,500–2,100 running, 2,500+ starting
- Fuel: Gasoline, or dual fuel for longer storage
- Type: Inverter generator (quieter, cleaner power)
- CO shut-off: yes — make it a must
- Outlets: Standard 120V household outlets
Models that could fit
Best fit
Westinghouse iGen2550DFc
Dual-fuel generator
- Power:
- 1,900 running / 2,550 starting W
- Fuel:
- Gas or propane (1,700 W on propane)
- CO shut-off:
- Yes
- CARB (California):
- No
Why it fits you: Covers your 1,250 running W, handles the 2,500 W start-up, for home backup.
Budget-friendly
WEN 56250iX
Inverter generator
- Power:
- 1,900 running / 2,500 starting W
- Fuel:
- Gasoline
- CO shut-off:
- Yes
- Noise:
- 65 dB (at 25% load; distance not stated)
- CARB (California):
- No
Why it fits you: Covers your 1,250 running W, handles the 2,500 W start-up, for home backup.
Battery option
BLUETTI Elite 100 V2
Power station (battery)
- Capacity:
- 1,024 Wh
- Inverter:
- 1,800 W (surge 2,700 W)
- Fuel:
- None — battery
- Battery:
- LiFePO4
- Noise:
- 30 dB (under 600 W load; distance not stated)
- CARB (California):
- Not needed (no engine)
Why it fits you: Covers your 1,250 running W, about 0.7 h at your full load, for home backup.
We don't test units ourselves; figures come from manufacturer spec sheets and the sources linked.
Read next: What size generator for a sump pump?
AC boxes say BTU. Generators say watts. The two look like they should convert with one simple number, and for heaters they do. For air conditioners, they don't, and that trips up a lot of people sizing a generator.
What is a BTU?
A BTU (British thermal unit) is an amount of heat. On an air conditioner, the rating is really BTU per hour: how much heat it can pull out of the room each hour. ENERGY STAR's sizing chart, for example, suggests about 8,000 BTU per hour for a 300 to 350 sq ft room.
The plain conversion: 1 W = 3.412 BTU/h
The U.S. Energy Information Administration lists 1 kilowatt-hour = 3,412 BTU. That works out to:
- 1 watt = 3.412 BTU per hour
- BTU/h ÷ 3.412 = watts
This is right for anything that turns electricity straight into heat. A 1,500 W space heater gives about 1,500 × 3.412 = 5,118 BTU/h.
Why an AC is different
An air conditioner doesn't make cold out of electricity. It uses a compressor to move heat from inside to outside. Moving heat takes far less power than making it. So a 12,000 BTU AC doesn't use 12,000 ÷ 3.412 = 3,517 W. It uses a fraction of that.
The number that links them is the AC's efficiency ratio. The Department of Energy's test method rates room ACs in BTU per watt-hour. You'll see it on labels as EER, CEER or, for mini splits and central AC, EER2.
Running watts ≈ BTU per hour ÷ EER
How many watts does a 12,000 BTU air conditioner use?
It depends on its EER. Here's the formula worked through, plus what ENERGY STAR's list shows:
| AC size | At EER 10 (older) | At EER 12 | ENERGY STAR room ACs (BTU ÷ CEER) |
|---|---|---|---|
| 5,000 BTU | 500 W | 420 W | about 350–365 W |
| 8,000 BTU | 800 W | 670 W | about 500–550 W |
| 10,000 BTU | 1,000 W | 830 W | about 625–710 W |
| 12,000 BTU | 1,200 W | 1,000 W | about 750–860 W |
The last column is our math on ENERGY STAR's certified room AC list (October 2026): each model's capacity divided by its CEER, middle 80% of models. CEER is a combined, all-season figure. On a very hot day the AC can draw more than this, so plan on the higher columns for a generator.
Mini splits are often more efficient still. ENERGY STAR data puts a typical 12,000 BTU mini split at about 860 to 1,000 W at 95°F. See will a generator run a mini split.
Don't forget the start-up surge
A compressor is a motor, so it needs a burst of extra watts to start. Our calculator uses these figures:
- Window AC, 8,000 BTU: 750 running, 2,000 starting
- RV AC, 13,500 BTU: 1,500 running, 3,000 starting
- RV AC, 15,000 BTU: 2,000 running, 3,500 starting
RV rooftop units use more than a window AC of the same size. Champion's chart lists 1,500 to 2,000 running watts for a 13,500 BTU RV AC. Read why surges matter in running vs starting watts.
How to find your AC's real watts
- Read the label on the side or back. Look for watts, or amps.
- If it lists amps, multiply by the volts: 7 A × 115 V ≈ 800 W.
- If it lists only BTU and EER, divide: BTU ÷ EER.
- Then add the surge using the figures above, or a soft start if you have one.
Sizing a generator for AC
Use running watts for the AC plus everything else, then add the AC's surge if it's the biggest motor. The calculator above starts with an 8,000 BTU window AC, a fridge and lights. Our guides go deeper:
- Generator for a window AC
- Will a 2,000 watt generator run a 13,500 BTU RV AC?
- Will a generator run central air?
Safety: Run it outdoors only, 20+ feet from the house, away from windows and doors. Read our carbon monoxide guide.
We don't test units ourselves; figures come from manufacturer spec sheets and the sources linked. How we research.
Sources
- U.S. EIA: British thermal units (1 kilowatthour = 3,412 Btu)
- eCFR, 10 CFR 430 Subpart B, Appendix F (DOE room AC test method): efficiency ratio in Btu per watt-hour; cooling capacity in Btu/h
- ENERGY STAR certified room air conditioners (data set: cooling capacity and CEER)
- ENERGY STAR: room air conditioners (capacity needed by room size)
- ENERGY STAR certified mini-split heat pumps (data set)
- Champion Power Equipment: generator wattage chart (AC running and starting watts)